Electrical and communication¶
Power, wiring and the CAN FD bus.
Power¶
| Specification | Value |
|---|---|
| Operating voltage | 20–50 VDC wide input |
| Continuous stall current | 6 A at 24 VDC |
| Standby power | < 7.2 W |
| Power connector | XT30-M |
Communication¶
| Specification | Value |
|---|---|
| Bus | CAN FD |
| Connector | A1257H-CJT |
| Low-level current loop | 10 kHz |
| High-level communication | 200 Hz |
| Host adapter | CAN FD to USB converter board, included |
Tactile data has its own CAN FD port. See Tactile interface.
Draft
Still to be written: wiring diagram, recommended power supply, status lights and the CAN FD protocol for users who skip the SDK.